Atlantic Ultraviolet MP49C User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
CAT730.4
102 Charbonnet Road 6 Duson, Louisiana 70529 6 337 988 2360 6 Fax 337 981 7922
[email protected] 6 Revised 09/10/08
DELIVERING EXPERIENCE, QUALITY, AND SERVICE SINCE 1934
- 1 to 9 gallons per minute [gpm], 60 to 540 gallons per hour [gph]
- Potable & high purity water point of use applications
- 304 Stainless Steel, electropolished and passivated inside and out
- Easy-Off
Retainer Cap for effortless lamp change
Unit Dimensions
(in.)
Shipping
Data (lb.)
Model
GPM GPH
Inlet
and
Outlet
[NPT](1)
Replacement
Lamps
Power
Consumption
[Watts] (2)
LengthWidthHeight
Gross
Wt.
Net
Wt.
Min-1 1 60 1/4" 05-1119 14 12-3/8 2-1/2 3 6 5
Min-
1.5
1.5 90 1/4" 05-1366 16 15-3/8 2-1/2 3 7 6
Min-3 3 180 3/4" 05-1366 16 16-1/4 4-1/4 5-9/16
10 9
Min-6 6 360 3/4" 05-1370 24 22-1/4 4-1/4 5-9/16
11 10
Min-9 9 540 3/4" 05-0097A 34 29-3/8 4-1/4 5-9/16
14 12
(1) Min-1 and Min-1.5 have female pipe threads. Min-3, Min6 & Min-9 have male pipe
threads.
(2) Total power consumption including ballast loss (approximately).
• Maximum recommended operating pressure for all purifiers is 100 PSI.
• Pressure drop at maximum recommended flow rate is less than 5 PSI.
• Consult factory with specific power requirements.
• All data shown above reflects 120 Volt 60 Hz operation.
Minipure® units are available
for operation on public power supplied throughout the world.
- 2 to 20 gallons per minute [gpm], 120 to 1200 gallons per hour [gph]
- Potable & high purity water applications
- 316 Stainless Steel, electropolished and passivated inside and out
- Easy-Off
Retainer Cap for effortless lamp change
- Drain Plug for in place drainage of the purifier
- Sight port to view germicidal lamp operation
Unit Dimensions
(in.)
Shipping
Data (lb.)
Model GPM GPH
Inlet
and
Outlet
[NPT](1)
Replacement
Lamps
Power
Consumption
[Watts] (2)
LengthWidthHeight
Gross
Wt.
Net
Wt.
MP13A 2 120 1/2" 05-1400-R 14 13-1/2
4-
5/16
8-3/16
9 8
MP16A 3 180 3/4" 05-1098-R 18 19-1/2
4-
5/16
8-3/16
10 9
MP22A 6 360 3/4" 05-1097-R 24 22-1/2
4-
5/16
8-3/16
13 11
MP36C 12 720 1" 05-1343-R 44 36-1/2
5-
11/16
9-1/2 30 25
MP49C 20 1,200 1-1/2" 05-1334-R 54 49-1/2
5-
11/16
9-1/2 34 29
CE/RoHS
MP36C 12 720 1" 05-1343-R 44 36-1/2
5-
11/16
9-1/2 30 25
(1) All inlets and outlets are male pipe thread.
(2) Total power consumption including ballast loss (approximately).
• Maximum recommended operating pressure for all purifiers is 100 PSI.
• Pressure drop at maximum recommended flow rate is less than 5 PSI.
• All data shown reflects 120 Volt 60 Hz operation.
• MightyPure is available for operation on public power supplied throughout the world.
t factory with specific power requirements. • Consul
Page view 3
1 2 3 4 5 6

Comments to this Manuals

No comments